SHB1 Weighing module

The weighing module amplifies the weak analog signal output by the sensor by a certain multiple to meet the requirements of the A/D converter for the input signal level. The function of A/D conversion is to convert analog signals into digital signals, carry out analog-to-digital conversion, then send the digital signals to the display circuit, and finally display the measurement results by the display circuit.

Product details
020-34563445

The weighing module is based on the principle of full-bridge measurement, and through the linear relationship between the output voltage of the circuit and the standard weight, the voltage dimension V is changed to the weight dimension G, which becomes an original Electronic scale. Among them, the most important component in the measuring circuit is the resistance strain weighing module.

Full-bridge measuring circuit is used as the most widely used metering module, which makes the system produce smaller errors and output more accurate data. The function of the three-operation amplifier circuit is to amplify the weak analog signal output by the sensor by a certain multiple to meet the requirements of the A/D converter for the input signal level. The function of A/D conversion is to convert analog signals into digital signals, carry out analog-to-digital conversion, then send the digital signals to the display circuit, and finally display the measurement results by the display circuit.

The weighing module adopts the electronic weighing device integrating modern sensor technology, electronic technology and computer technology, so as to meet and solve the "fast, accurate, continuous and automatic" weighing requirements put forward in real life, and at the same time effectively eliminate human errors, making it more in line with the application requirements of legal metrology management and industrial production process control.

technical parameter

Accuracy grade: 0.02%

Rated range (kg): 110, 220, 550, 1100, 1760.

Sensitivity (mV/V): 1.94

Sensitivity error range (%): 0.1000

Effect of temperature on sensitivity (%of cn/10k): 0.0140.

Influence of temperature on zero point (%of cn/10k): 0.0140

Nonlinear error (%of Cn):±0.0170

Lag error (%of Cn): ±0.0170

Creep and creep recovery for 30min s (%/30min): 0.0166.

Zero point balance (MV/V): 0 0.01

Input resistance (ω): 400 50

Output resistance (ω): 350 0.12

Reference voltage (V):5

Maximum working voltage (V): 5 ... 15

Insulation resistance (Gω/100 V): > 5

Rated temperature range (℃):-10 ~+40

Working temperature range (℃):-30 ~+70.

Storage temperature range (℃):-50 ~+85.

Safe bearer (%of Emax):150

Ultimate bearing capacity (%of Emax):100

Rated load Emax(% of Emax):300

Allowable dynamic load (%of Emax):70

Maximum load deformation (mm):0.5

Weight (kg):0.9

Protection grade: P68


Weighing and mixing machine in powder dosage system application program
The whole automatic batching system consists of industrial control machine, PLC, industrial weighing instrument, frequency converter, vibration motor, mixer, sensor, conveyor belt and other parts.
Application of weighing modules in large storage tanks
Weighing modules can be used as storage and irrigation materials in and out of the warehouse measurement, can also be used for process flow control, in general, according to the shape of the tank and the installation of different ways to choose 3 or 4 weighing modules to complete, especially suitable for chemical plant production process quantitative feeding system occasions to use.
Application Design of Weighing Mixer
Weighing and mixing machine through PLC to control the frequency converter, so that the speed motor drives the metering screw according to the set speed running down the material. The whole weighing and dosing system can be divided into small material weighing, large material weighing and micro material weighing. It adopts the way of uniform speed feeding, and the way of decreasing speed feeding is adopted in the low speed stage.
×